200kVA Cummins C220 D5E 3 Phase Silent Generator
with: Battery Charger, Water Heater, Set Mounted 4-pole Circuit Breaker, 464 litre Base Fuel Tank & Close Fit Acoustic Canopy (77 dBA @ 1m)
- Prime 200 kVA 160 kWe
- Standby 220 kVA 176 kWe
- Engine QSB7G5
- Alternator UCI274H
- Phase 3
- Voltage 380 – 415V
- Amps per Phase 318
- Control PanelPowerCommand 1.2
250 kVA Cummins C275 D5 3 Phase Silent Generator
with: Battery Charger, Water Heater, Set Mounted 4-pole Circuit Breaker, 691 litre Base Fuel Tank & Close Fit Acoustic Canopy (77 dBA @ 1m)
- Prime 250 kVA 200 kWe
- Standby 275 kVA 176 kWe
- Engine QSL9G5
- Alternator UCDI274K
- Phase 3
- Voltage 380 – 415V
- Amps per Phase 397
- Standard Controller Automatic Start
80kVA Perkins diesel generator
- 80KVA Prime Power / 89KVA Maximum Power
- High quality UK made Perkins Engine (1104A-44TG2)
- High quality Stamford Alternator (UCI 224G)
- Standby Amps 135
- Deep Sea Electronics 7120 MK2 controller.
100 kVA Cummins C110D5 3 Phase Diesel Generator
with: Battery Charger, Water Heater, Set Mounted 4-pole Circuit Breaker, 350 litre Base Fuel Tank & Close Fit Acoustic Canopy (78 dBA @ 1m)
- Prime Power: 100 kVA / 80 kWe
- Standby Power: 110 kVA / 88 kWe
- Engine: 6BTA5.9G5
- Alternator: UCI274C
125 kVA Cummins C150 D5 3 Phase Silent Generator
with: Water Heater, Set Mounted 4-pole Circuit Breaker, 448 litre Base Fuel Tank & Close Fit Acoustic Canopy (76 dBA @ 1m)
- Prime 125 kVA 100 kWe
- Standby 138 kVA 110 kWe
- Engine 6BTAA5.9G6
- Alternator UCI274E
150 kVA Cummins C170 D5 3 Phase Silent Generator
with: Battery Charger, Water Heater, Set Mounted 4-pole Circuit Breaker, 448 litre Base Fuel Tank & Close Fit Acoustic Canopy (79 dBA @ 1m)
- Prime 150 kVA 124 kWe
- Standby 165 kVA 136 kWe
- Engine 6BTAA5.9-G7
- Alternator UCI274CF
- Phase 3
- Voltage 380 – 415V
- Amps per Phase 245
- Standard Controller Automatic Start
180kVA Cummins C200 D5e 3 Phase Silent Generator
182 kVA Cummins C200 D5e 3 Phase Silent Generator
with: Stage 3a Cummins Engine, Battery Charger, Water Heater, Set Mounted 4-pole Circuit Breaker, 464 litre Base Fuel Tank & Close Fit Acoustic Canopy (76 dBA @ 1m)
- Prime 180 kVA 146 kWe
- Standby 200 kVA 160 kWe
- Engine QSB7G5
- Alternator UCI274H
- Phase 3
- Voltage 380 – 415V
- Amps per Phase 289
- Standard Controller Automatic Start
30kVA 3 Phase Generator – Perkins diesel generator
- 30KVA Prime Power / 33KVA Maximum Power
- High quality UK made Perkins Engine (1103A-33G)
- High quality Stamford Alternator (S0L2-P1)
- Standby Amps 50
- Deep Sea Electronics 7120 MK2 controller.
40kVA / 32KW Three Phase Silent Diesel Generator
Prime: 40 kVA / 32 kW
Standby: 44 kVA / 35 kW
Engine: Cummins 4BTAA3.3-G14 (Stage IIIa)
Alternator: Stamford UCI22 4C
Voltage: 380-415V
Frequency: 50Hz
Amps Per Phase: 63.3
Control Panel: PS0600
50 kVA Cummins C55 D5e 3 Phase Silent Generator
- Prime 50 kVA 40 kWe
- Standby 55 kVA 44 kWe
- Engine Cummins 4BTAA3.3-G14
- Alternator UCi224D
60 kVA Cummins C66 D5e 3 Phase Silent Generator
- Prime 60 kVA / 48 kWe
- Standby 66 kVA / 52.8 kWe
- Engine Cummins 4BTAA3.3-G14
- Alternator UCi224F
75kVA / 60kW Perkins Silent Generator
3 phase,50HZ@1500RPM
Prime power: KVA 75 / KW 60
Standby power: KVA 77 / KW 61.6
Voltage V 400/230
Ampere A 127.1